Grizzl-E Ultimate Pro 80A: specs, charging speed and standby power
19.2 kW max output · 80 A · 24 ft cord · 5.9 W standby (ENERGY STAR)
Certified specs
| Type | Level 2 |
|---|---|
| Maximum output power | 19.2 kW |
| Max nameplate output current | 80 A |
| Input voltage | 240 V |
| Number of outputs | 1 |
| Output cord length | 24 ft |
| Cord gauge | 6 AWG |
| Network capable | Yes |
| Network protocol | Wi-Fi or Gigabit Ethernet |
| Other features | High Resolution Display,Radio Frequency Identification (RFID) |
| No-vehicle-mode power (standby) | 5.9 W |
| Partial-on-mode power | 5.9 W |
| Idle-mode power (car connected, not charging) | 7.11 W |
| Total loss at full current (test) | 233 W |
| High-res display area | 10.62 in² |
| Markets | United States, Canada |
| Date available on market | 2026-06-30 |
| Date certified | 2026-06-30 |
| ENERGY STAR partner | United Chargers Inc. |
| Model number(s) as listed | GRU-077-WLR-HW-25J80-P-GB |
| Source | ENERGY STAR record 4661654 · Product Finder page |
How much range does it add per hour?
Estimate: miles per hour of charging = charger kW ÷ the car's EPA electricity use (kWh per 100 miles, measured at the wall) × 100. Only valid if the car's onboard charger accepts 19.2 kW; many EVs accept 7–11.5 kW on AC, so a bigger charger won't charge them faster.
| EV (median-efficiency trim) | Range added per hour | Est. hours, empty to full EPA range |
|---|---|---|
| Tesla Model Y (Model Y Standard AWD, 26.5 kWh/100 mi) | 72 mi | 4.1 h |
| Tesla Model 3 (Model 3 Performance, 29.6 kWh/100 mi) | 65 mi | 4.8 h |
| Chevrolet Equinox EV (Equinox EV AWD (11 kW Charger), 32.6 kWh/100 mi) | 59 mi | 5.2 h |
| Ford F-150 Lightning (F-150 Lightning 4WD PRO ER1, 47.9 kWh/100 mi) | 40 mi | 8.0 h |
| Hyundai Ioniq 5 (Ioniq 5 AWD (20inch Wheels), 34.5 kWh/100 mi) | 56 mi | 4.8 h |
| Ford Mustang Mach-E (Mustang Mach-E AWD, 33.6 kWh/100 mi) | 57 mi | 4.2 h |
| Kia EV9 (EV9 Long Range AWD GT-Line, 41 kWh/100 mi) | 47 mi | 6.0 h |
| Rivian R1S (R1S Premium Long Range (20in AT), 43.2 kWh/100 mi) | 44 mi | 8.3 h |
Vehicle figures: fueleconomy.gov. Real charging slows near 100% and in cold weather. Try your own car and battery level.
Circuit and breaker
At 80 A continuous, the circuit typically needs to be rated for at least 125% of the charger's load: 100 A, which usually means a 100 A breaker (estimate based on the NEC continuous-load rule; your electrician and local code decide). Many chargers can be set to a lower current for smaller circuits.
Standby electricity
With no car connected it draws 5.9 W; with a car connected but not charging, 7.11 W. If left in no-vehicle mode all year, that is at most about 52 kWh/yr ≈ $9.46 at the U.S. average rate (estimate).
Other brands with the same 19.2 kW output, lowest standby first
| Charger | Max output | Max current | Cord | Wi-Fi/network | Standby (no vehicle) | Max standby cost/yr* |
|---|---|---|---|---|---|---|
| Enphase CS-100 EVSE | 19.2 kW | 80 A | 18 ft | Yes | 2.49 W | $3.99 |
| Leviton EV800 | 19.2 kW | 80 A | 18 ft | Yes | 2.62 W | $4.20 |
| Leviton EV80G | 19.2 kW | 80 A | 25 ft | Yes | 2.63 W | $4.22 |
| Leviton EV80W | 19.2 kW | 80 A | 18 ft | Yes | 2.78 W | $4.46 |
| FLO Home | 19.2 kW | 80 A | 25 ft | Yes | 3.28 W | $5.26 |
| Blink IQ 200 Smart | 19.2 kW | 80 A | 24 ft | Yes | 3.5 W | $5.61 |
| Siemens VersiCharge Blue | 19.2 kW | 80 A | 25 ft | Yes | 3.87 W | $6.21 |
| Blink Series 7 | 19.2 kW | 80 A | 23 ft | Yes | 4.07 W | $6.53 |
*Estimate: ENERGY STAR "no vehicle mode" input power × 8,760 h, i.e. the most it could use in a year if no car were ever plugged in, × U.S. average residential rate 18.31¢/kWh (EIA, July 2026 (preliminary)).
Compare this charger side by side with any other · All Grizzl-E chargers
See Grizzl-E EV chargers on the manufacturer's site (plain link, not an affiliate link)
We have not tested this product. Figures are as listed in ENERGY STAR data retrieved 2026-10-17.